Condensation on Windows: Three Places, Three Causes

Condensation on the inside of a window pane in a cold room

Between November and March, every window installer gets the same phone call: the new windows are "causing condensation". Almost always they are not. Where the water sits tells you what is actually wrong, and only one of the three places is a fault with the product. Here is how to work out which one you are looking at, and what to say.

The short answer

On the room side of the glass it is humidity and ventilation. Between the panes the sealed unit has failed. On the outside the glass is doing its job. Only the middle one is a product fault.

1. Condensation on the room side

Warm air holds more moisture than cold air. When moist indoor air meets a surface colder than its dew point, the moisture condenses out onto that surface. In most rooms the coldest surface is the glass, which is why the window gets the blame for a problem that belongs to the air in the room.

The moisture comes from ordinary living: showers and baths, cooking, washing dried on radiators, unvented tumble dryers, and the occupants themselves. A family of four puts several litres of water into the air every day without doing anything unusual.

So room-side condensation is a moisture and ventilation question, not a glazing fault. It is cleared by extracting moisture at source in kitchens and bathrooms, by providing background ventilation, and by not drying washing indoors on a closed-up house.

2. Why it often starts right after new windows go in

This is the one that turns into a callback, and it is worth being ready for.

The old windows leaked. Air escaped around tired frames, past worn seals and through sashes that no longer closed properly, and it carried moisture out of the building with it. That ventilation was accidental, uncontrolled and wasteful, but it was doing a job.

A modern window seals properly. The moisture that used to drift out through the gaps now stays in the room, and it shows up on the coldest surface it can find. Nothing has gone wrong with the window. The house has lost the uncontrolled ventilation it used to rely on, which is exactly why controlled ventilation has to replace it.

3. What Approved Document F requires

The updated Approved Document F came into force on 15 June 2022, and the principle that matters on replacement work is "no worse than before": a replacement window must not make a room's background ventilation worse than it was.

Ventilation is measured as equivalent area (EA) in mm², which describes how much air actually flows through, not how big the slot looks. Habitable rooms typically call for around 8,000 mm² EA, with wet rooms and smaller spaces differing. Check the EA figure the trickle vent manufacturer publishes rather than judging it by eye.

In practice, because most windows being replaced either had vents or leaked air around the frame, the compliant path is nearly always to include trickle vents in the new units. There is more detail on that in our guide to trickle vents and Document F.

4. Condensation between the panes

If the moisture is inside the sealed unit, sitting between the two panes, the edge seal has failed and the desiccant in the spacer bar is saturated. This is the one case where the product has genuinely failed, and the unit gets replaced.

The tell-tale is simple: a misty or streaky haze that you cannot wipe off from either side, because the affected surfaces are sealed inside the unit. No amount of ventilation, heating or wiping will clear it, and it usually gets worse as the temperature swings through the day.

5. Condensation on the outside of the glass

Most common on a clear, still morning in spring or autumn. The outer pane has dropped below the dew point of the outside air because very little heat is reaching it from inside the house.

On a well insulated unit, that is precisely what should happen. The heat is staying where the customer paid for it to stay. It clears as the sun comes up, and it is worth flagging before it happens, because customers often read it as a fault when it is the opposite.

What to check on a condensation callout

  • Which surface is the water on? Room side, between the panes, or outside. That answers most of it before you do anything else.
  • Can you wipe it off? If you cannot, and it sits between the panes, the sealed unit has failed.
  • Do the wet rooms have working extract? A disconnected or painted-over extract fan is a common culprit.
  • Are there trickle vents, and are they open? Vents taped or screwed shut by the occupant are surprisingly common.
  • Is washing being dried indoors? On an airer in a sealed room it will find the glass every time.

The conversation worth having before the order

Most condensation complaints are really expectation complaints, and they are far easier to handle before the job than after it.

Agree the look of the trickle vents up front, because that is the objection that tempts people into leaving them out. Explain that a tighter house needs deliberate ventilation to replace the draughts it has just lost. And mention external condensation before the customer sees it for the first time, so it arrives as evidence the units are performing rather than as a defect.

Do that and the winter phone call becomes a two minute conversation instead of a site visit.